π₯ Ingestion Sourcesο
Sources define how data enters EdgeStream Hub. They either listen on local network ports to accept incoming logs, or connect out to external services, message queues, and cloud platforms to pull data in.
Available Source Typesο
EdgeStream Hub supports multiple connectors designed for standard system, network, and cloud formats:
Cloud & Messagingο
Office 365 Audit (
o365audit): Connects to the Microsoft 365 Management Activity API to collect audit and security events from Microsoft 365, Entra ID (Azure AD), Exchange, SharePoint, and DLP.Audit.General: Microsoft Teams, Defender alerts, OneDrive actions, Sway, and Planner telemetry.Audit.AzureActiveDirectory: User logins, role assignments, directory modifications, and credential updates.Audit.Exchange: Mailbox activity, admin delegation changes, and mail policy events.Audit.SharePoint: Document library activities, file permissions, and site administration.DLP.All: Data Loss Prevention matches and policy incidents.AWS SQS (
aws_sqs): Pulls messages directly from an Amazon Simple Queue Service standard or FIFO queue.AWS S3 (
aws_s3): Downloads and processes log archives stored in an Amazon S3 bucket, triggered by SQS bucket notification messages.
Network & Security Systemsο
Syslog (
syslog): Listens for standard RFC 3164 and RFC 5424 syslog messages over UDP, TCP, or encrypted TLS.NetFlow (
netflow): Receives and parses Cisco NetFlow (v5, v7, v9) and IPFIX network traffic flows over UDP.CEF (
cef): Ingests Common Event Format security logs produced by firewalls, security appliances, and SIEM forwarders.Raw Socket (
socket): A general-purpose network listener for raw TCP, UDP, or Unix socket streams.
Agents & Log Shippersο
Logstash / Beats (
logstash): Accepts connections from Elastic Beats agents (Winlogbeat, Filebeat, Metricbeat) using the Lumberjack protocol.Fluent (
fluent): Accepts log streams sent from Fluentd or Fluent Bit forwarders.OpenTelemetry (
opentelemetry): Listens for standard OpenTelemetry log and trace data over HTTP or gRPC.Vector (
vector): High-speed direct streaming between EdgeStream Hub nodes or upstream forwarders.Splunk HEC (
splunk_hec): Receives events sent to the Splunk HTTP Event Collector format without needing to modify forwarder configurations.HTTP Server (
http_server): Hosts a web endpoint to receive logs and webhooks sent as HTTPPOSTrequests.HTTP Client (
http_client): Regularly queries a remote website or REST API to fetch new data records.File (
file): Reads and monitors log files directly from the local server filesystem (such as/var/log/**/*.log).Windows Event Collector (
wec): (Coming Soon) Ingests events directly from domain-joined Windows machines using native Windows Event Forwarding.
System & Health Metricsο
Host Metrics (
host_metrics): Collects hardware and operating system metrics from the EdgeStream Hub server itself (CPU, memory, disk usage, and network traffic).Internal Metrics (
internal_metrics): Tracks the real-time operational health, processing rates, and error counters of EdgeStream Hub.PostgreSQL Metrics (
postgresql_metrics): Connects to a PostgreSQL database instance to monitor database health, active connections, and query statistics.
Automatic Event Taggingο
Whenever data enters through any source, EdgeStream automatically adds identification labels to each record:
Label |
Example Value |
Description |
|---|---|---|
|
|
The friendly name assigned to the source instance. Used for routing and filtering rules. |
|
|
The connector type handling the data. |
|
|
The event timestamp from the message header, or the time EdgeStream received the log if missing. |
How to Create a Sourceο
In the left navigation, go to Administration β Configuration β Sources.
Click Create in the upper-right corner.
Configure the general properties:
Enabled: Check this box so the source starts running as soon as you save it. (Leave unchecked if you want to set it up now and enable it later).
Name: A unique identifier using letters, numbers, hyphens, or underscores (for example,
prod_firewall_syslog).
Warning
Source Names Are Permanent: Once created, a source cannot be renamed because downstream filters and destinations refer directly to this name. If you need to rename a source, you must create a new one with the desired name and delete the old one.
Type: Select the matching connector type from the dropdown.
Completing the Settings Drawerο
The settings drawer automatically updates based on the source type you choose:
Base Settings (Required): The primary connection detailsβsuch as the listening port, server address, queue URL, or account credentials. If you enter a listening port, the system verifies that the port is free before saving.
TLS Settings (Optional / As Needed): For encrypted streams, toggle TLS on and specify your certificate and key files.
Optional Settings: Pre-configured defaults for line splitting, character sets, and connection limits. You can leave these at their default values unless your environment requires specific tuning.
Click Create to save and activate the source.
Connecting Sources to Destinationsο
Creating a source only brings data into the applianceβit does not forward it automatically unless routed:
If a Default Destination Exists: If your system has a default destination enabled under Administration β Configuration β Destinations, all new sources automatically send their data there.
To Route to a Specific Destination:
Go to Administration β Configuration β Destinations.
Click Edit next to the target destination (such as an S3 bucket or ClickHouse database).
Under the Inputs / Events and Metrics list, select your new source.
Save the destination.
Important
If you do not have a default destination set and do not link your source to a specific destination, any events received by this source will be discarded immediately upon arrival (blackholed).
Managing Existing Sourcesο
Editing Settings: Click Edit next to any listed source to update connection settings, renew certificates, or modify parsing options.
Pausing a Source: Open the source edit menu, uncheck Enabled, and save. The source will stop listening or polling without deleting your configuration.